Strona 1 - Serial Data Debug Solutions

Serial Data Debug Solutions Operator's Manual August, 2011

Strona 2

Serial Data Debug Solutions 10 919586 RevA  PROTObus MAG - The PROTObus MAG Toolset equips certain protocols (I2C, SPI, UART, RS-232, CAN, LIN, Flex

Strona 3 - TABLE OF CONTENTS

Serial Data Debug Solutions 100 919586 RevA Note: The Clear Label Filter button resets all your labels to empty values so you can start your filter se

Strona 4

Operator's Manual 919586 RevA 101 ARINC 429 Decode Annotations  Label - Identifier showing data type and parameter association. Typically show

Strona 5

Serial Data Debug Solutions 102 919586 RevA Make selections as desired. You can also set a BitRate Tolerance percentage or touch the Default button to

Strona 6

Operator's Manual 919586 RevA 103 MIL-STD-1553 Decode Setup Detail For general information about using controls shown on the main Serial Decode d

Strona 7

Serial Data Debug Solutions 104 919586 RevA MIL-STD-1553 Decode Trace Annotations Like all trace annotations, MIL-STD-1553 Decode annotations are rect

Strona 8

Operator's Manual 919586 RevA 105 MIL-STD-1553 Decode Table Column Details MIL-STD-1553 table column values available include the following: Mak

Strona 9 - Overview

Serial Data Debug Solutions 106 919586 RevA MIL-STD-1553 Decode Search After clicking the Search button from the Decode dialog, the Zoom dialog is sho

Strona 10

Operator's Manual 919586 RevA 107 MIL-STD-1553 Trigger Setup Detail The following topics show the main and right hand dialog selections for a MIL

Strona 11

Serial Data Debug Solutions 108 919586 RevA Sub-Types, Setup Format, and Right-Hand Dialogs TRANSFER SUB-TYPES, SETUP FORMAT, AND RIGHT-HAND DIALOGS 4

Strona 12 - The D and TD Toolsets

Operator's Manual 919586 RevA 109  DW Right-Hand Dialog - Provide Data Pattern Setup field values for Data Condition,Start Bit and # Data Bits,

Strona 13

Operator's Manual 919586 RevA 11 Protocol D TD PROTObus MAG ProtoSync P, G, Toolsets* I2C • • • SPI • • • UART, RS-232 • • • CAN • •

Strona 14

Serial Data Debug Solutions 110 919586 RevA RT-RT Sub-Type and Right-Hand Dialogs When the RT-RT sub-type is selected, the TxCmd1, RxCmd2, DW, TxStat1

Strona 15

Operator's Manual 919586 RevA 111  TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition, Value,

Strona 16

Serial Data Debug Solutions 112 919586 RevA  TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition, Va

Strona 17

Operator's Manual 919586 RevA 113  RxCmd2 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition, Value,

Strona 18

Serial Data Debug Solutions 114 919586 RevA  TxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition, Va

Strona 19

Operator's Manual 919586 RevA 115  RxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition, Value,

Strona 20

Serial Data Debug Solutions 116 919586 RevA Status Sub-Type and Right-Hand Dialog When the Status sub-type is selected, the Status right-hand dialog

Strona 21

Operator's Manual 919586 RevA 117 Response Time Right-Hand Dialog Provide Response Time Setup... values for Condition, Value, and To (for range

Strona 22

Serial Data Debug Solutions 118 919586 RevA Handset, Cellular, and Mobile Computing Protocols Handset, Cellular, and Mobile Computing Protocols Overvi

Strona 23

Operator's Manual 919586 RevA 119 DIGRF 3G VIEW I & Q BUTTON AND MIPI DIGRF 3G RIGHT-HAND DIALOG Access the Serial Decode dialog by touching

Strona 24

Serial Data Debug Solutions 12 919586 RevA Accessing and Using Supported Protocol Toolsets Accessing and Using Supported Protocol Toolsets Overview Le

Strona 25

Serial Data Debug Solutions 120 919586 RevA  Hysteresis (V) - Provide a desired voltage level for the Hysteresis. Setup  Speed-mode - Choose from

Strona 26 - The ProtoSync Toolset

Operator's Manual 919586 RevA 121 DigRF 3G Decode Table Column Details DigRF 3G table column values available include the following: Make select

Strona 27

Serial Data Debug Solutions 122 919586 RevA DigRF 3G Decode Search After clicking the Search button from the Decode dialog, the Zoom dialog is shown a

Strona 28

Operator's Manual 919586 RevA 123 DigRF v4 Decode Setup Detail For general information about using controls shown on the main Serial Decode dialo

Strona 29

Serial Data Debug Solutions 124 919586 RevA You can touch buttons on the View I & Q Wizard pop-up to View Constellation (XY) or View Parameters. 

Strona 30

Operator's Manual 919586 RevA 125 Probing/Level  Probing - Choose from One Differential and Two Single Ended values.  Level - Provide a desir

Strona 31

Serial Data Debug Solutions 126 919586 RevA  Comment - Another user-defined column. Define/customize this column by modifying the same DigRFv4_B10I.

Strona 32 - Debug Examples

Operator's Manual 919586 RevA 127 After setting up your DigRF v4 decode and checking the View Table checkbox, the table should be shown just bene

Strona 33

Serial Data Debug Solutions 128 919586 RevA  RTI - Re-Transmission Indicator  CRC - Coherency Redundancy Check  EoF - End of Frame Customizing W

Strona 34

Operator's Manual 919586 RevA 129 MIPI D-PHY SOURCE AND CLOCK CONTROLS, BASIC, AND LEVELS RIGHT-HAND DIALOGS Access the Serial Decode dialog by t

Strona 35

Operator's Manual 919586 RevA 13 Note: Although the decoding algorithm is based on a clock extraction software algorithm using a vertical level,

Strona 36

Serial Data Debug Solutions 130 919586 RevA D-PHY Level Right-Hand Dialog  VIH(min) - Provide a minimum voltage amount for your decode. Provide a v

Strona 37

Operator's Manual 919586 RevA 131  Symbols  Bits/Resolution  Pad  Status Note: Specifications are subject to change without notice. MIPI

Strona 38

Serial Data Debug Solutions 132 919586 RevA MIPI D-PHY Decode Search After clicking the Search button from the Decode dialog, the Zoom dialog is shown

Strona 39

Operator's Manual 919586 RevA 133  Data  DataL1  DataL2  DataL3  DataL4  CS  CSL1  CSL2  CSL3  CSL4  HS0  HS1  HSBITS 

Strona 40

Serial Data Debug Solutions 134 919586 RevA Enable Marking the Enable checkbox enables the controls on the dialog. Notice how MIPI D-PHY provides its

Strona 41

Operator's Manual 919586 RevA 135 Setup Acquisition The Setup Acquisition button automatically makes the following settings. The settings are lar

Strona 42

Serial Data Debug Solutions 136 919586 RevA OR Go directly to its corresponding test dialog and enable/disable it from there. Additional controls for

Strona 43

Operator's Manual 919586 RevA 137 Category and Measure Combinations for LP Dphy1 - X Dialogs BRIEF LP LEVELS TEST DESCRIPTIONS  With LP Levels

Strona 44

Serial Data Debug Solutions 138 919586 RevA BRIEF LP TIMING TEST DESCRIPTIONS  With LP Timing selected in the Category field, the following Measure

Strona 45 - Using the 8b/10b Option

Operator's Manual 919586 RevA 139 Name Purpose SR-RISE-700-930-MIN-CLKp SR-RISE-700-930-MIN-CLKn Official MIPI D-PHY Test Algorithms Specific tes

Strona 46

Serial Data Debug Solutions 14 919586 RevA Some oscilloscope models also allow you to access the Serial Decode dialog the following ways:  Touch the

Strona 47

Serial Data Debug Solutions 140 919586 RevA Name Purpose TLP-01 To verify that the duration (TLPX) of the final Data Lane LP-01 state immediately befo

Strona 48

Operator's Manual 919586 RevA 141 BRIEF HS CLOCK TIMING TEST DESCRIPTIONS  With HS Clock Timing selected in the Category field, the following M

Strona 49

Serial Data Debug Solutions 142 919586 RevA BRIEF HS COMMON MODE TEST DESCRIPTIONS  With HS Common Mode selected in the Category field, the followin

Strona 50

Operator's Manual 919586 RevA 143 BRIEF HS RISE & FALL TEST DESCRIPTIONS  With HS Rise & Fall selected in the Category field, the foll

Strona 51

Serial Data Debug Solutions 144 919586 RevA Show Eye Marking this checkbox shows the eye diagram trace on the display area and includes a correspondin

Strona 52

Operator's Manual 919586 RevA 145 Using the MIPI M-PHY Using the MIPI M-PHY Decode Option Overview The MIPI M-PHY decode option defines the next-

Strona 53 - Using the I2Cbus Option

Serial Data Debug Solutions 146 919586 RevA M-PHY Decode Right-Hand Dialog  Probing - Selections made from this control manage the corresponding so

Strona 54

Operator's Manual 919586 RevA 147  Payload  Data - Bits 29 - 11.  TAIL-OF-BURST  Bit Rate/Msg  Status  Attributes Note: Specification

Strona 55

Serial Data Debug Solutions 148 919586 RevA MIPI M-PHY Decode Search After clicking the Search button from the Decode dialog, the Zoom dialog is shown

Strona 56

Operator's Manual 919586 RevA 149 MIPI M-PHY DIALOG DETAILS Use the following sections to work through areas of the main dialog. Enable, Show Dec

Strona 57

Operator's Manual 919586 RevA 15 THE DECODE SETUP DIALOG The Decode Setup dialog is where the details of a specific protocol decode is entered. I

Strona 58 - Using the SPIbus Option

Serial Data Debug Solutions 150 919586 RevA Show Decode Note: If you do not have the MIPI D-PHY Serial Decode Option (D PHY-D), you won't see th

Strona 59

Operator's Manual 919586 RevA 151 SETUP ACQUISITION FOR HS HIGH SPEED MODE Your channels are set to 200 mV/div, -600 mV offset, and an Edge trigg

Strona 60

Serial Data Debug Solutions 152 919586 RevA Enabling Tests Enable/disable a test by either marking/unmarking its respective checkbox from the summary

Strona 61

Operator's Manual 919586 RevA 153  Touch the CDR control and select from Linear, Filtered, and Short-Term choices.  The next two controls all

Strona 62

Serial Data Debug Solutions 154 919586 RevA Storage, Peripherals, and Interconnect Protocols Storage, Peripherals, and Interconnect Protocols Overview

Strona 63

Operator's Manual 919586 RevA 155 PCIe PCIe is a computer expansion card standard designed for mainstream PCs to replace older parallel data PCI,

Strona 64

Serial Data Debug Solutions 156 919586 RevA SAS DECODER AND EXPORTER RIGHT-HAND DIALOGS Access the Serial Decode dialog by touching Analysis → Serial

Strona 65

Operator's Manual 919586 RevA 157 SAS Decode Trace Annotations Like all trace annotations, SAS Decode annotations are rectangular shadings used t

Strona 66

Serial Data Debug Solutions 158 919586 RevA Make selections as desired. You can also set a BitRate Tolerance percentage or touch the Default button to

Strona 67

Operator's Manual 919586 RevA 159  Grouped Primitives - With the Grouped Primitives Type selected, Any, AIP(NORMAL), AIP(RESERVED0), AIP(RESERV

Strona 68 - Using the CANbus Option

Serial Data Debug Solutions 16 919586 RevA  Touching anywhere else on the table shows a pop-up with Off, Zoom, Setup..., Export, and Measure... choi

Strona 69

Serial Data Debug Solutions 160 919586 RevA PCIEbus Decode Examples (on page 171). The capture was made with a high impedance differential probe at th

Strona 70

Operator's Manual 919586 RevA 161 FibreChannel Protocol Exporter Right-Hand Dialog The FibreChannel Protocol Exporter right-hand dialog provides

Strona 71

Serial Data Debug Solutions 162 919586 RevA FibreChannel Decode Table Column Details FibreChannel table column values available include the following:

Strona 72

Operator's Manual 919586 RevA 163 FibreChannel Decode Search After clicking the Search button from the Decode dialog, the FibreChannel Search rig

Strona 73 - Using the LINbus Option

Serial Data Debug Solutions 164 919586 RevA Correcting Poor Signal Quality or Inverted Signals It is important to provide a high quality signal when u

Strona 74

Operator's Manual 919586 RevA 165 PCIE-1X1 - One Lane Either Upstream or Downstream When selected, PCIE-1X1 shows Lane 0. Now, select a Source fo

Strona 75

Serial Data Debug Solutions 166 919586 RevA  Scrambling on (if no TS2) - Some PCIEbus standards use a scrambling algorithm to reduce electromagnetic

Strona 76

Operator's Manual 919586 RevA 167 The ProtoSync Right-Hand Dialog After setting up your specific Lane configuration, use the ProtoSync right-hand

Strona 77 - Using the FlexRaybus Option

Serial Data Debug Solutions 168 919586 RevA Messages shown as annotations, table columns, and search types for most protocols are classified into Fram

Strona 78

Operator's Manual 919586 RevA 169 The Table should be shown on the display grid as follows: Note: After touching the View Table checkbox, touch t

Strona 79

Operator's Manual 919586 RevA 17 5. Table #Rows - Touch this option and provide a value (1-20) for the number of table rows for display. One row

Strona 80

Serial Data Debug Solutions 170 919586 RevA The value of the next byte is annotated for TS2, the next 4 bytes for TS1; these bytes may contain equaliz

Strona 81

Operator's Manual 919586 RevA 171 PCIEbus Decode Examples Let's show some examples while performing a PCIEbus Decode setup. Start by touchin

Strona 82

Serial Data Debug Solutions 172 919586 RevA Automatic Zoom by Table Row Selection Continuing from the previous section, select the Idx 31 row on the t

Strona 83

Operator's Manual 919586 RevA 173 The following figure shows row Idx 34 selected and Z1 resized accordingly. The zoom position is adjusted corres

Strona 84

Serial Data Debug Solutions 174 919586 RevA Yellow is TS2, as shown. Notice how trace annotation rectangle colors are consistent among the source trac

Strona 85

Operator's Manual 919586 RevA 175 Proper Decode with Speed Change The following screen-shot shows an annotation on the source trace showing a spe

Strona 86

Serial Data Debug Solutions 176 919586 RevA SATA Decode Setup Detail For general information about using controls shown on the main Serial Decode dial

Strona 87 - Serial Audio Protocol

Operator's Manual 919586 RevA 177 SATA Decode Trace Annotations Like all trace annotations, SATA Decode annotations are rectangular shadings used

Strona 88

Serial Data Debug Solutions 178 919586 RevA SATA Decode Table Column Details SATA table column values available include the following: Make selection

Strona 89

Operator's Manual 919586 RevA 179 NAVIGATION FIELDS A Prev and Next button is on either side of the dialog to navigate through each search result

Strona 90

Serial Data Debug Solutions 18 919586 RevA Decode Toolset Features and Controls DECODE TOOLSET FEATURES AND CONTROLS OVERVIEW Data packets (or message

Strona 91

Serial Data Debug Solutions 180 919586 RevA SATA Trigger Setup Detail The following topic provides specific control settings for a SATA Trigger setup.

Strona 92

Operator's Manual 919586 RevA 181 Setup Mode Select Symbol OR to trigger on a logical OR combination of characters or Symbol String to trigger us

Strona 93

Serial Data Debug Solutions 182 919586 RevA PLEASE NOTE THE FOLLOWING:  Some additional reserved and vendor-specific FIS values are also available

Strona 94

Operator's Manual 919586 RevA 183 Using the USB2 Option Using the USB2 Option Overview The USB 2.0 decode option shows the packet level of the US

Strona 95

Serial Data Debug Solutions 184 919586 RevA Two Single Ended Probes With Two Single Ended Probes selected, separate data positive and data negative So

Strona 96

Operator's Manual 919586 RevA 185 Decode annotations unique to USB2 include the following (some annotations are not shown in the screen-shot): US

Strona 97 - Using the ARINC 429 Option

Serial Data Debug Solutions 186 919586 RevA Make selections as desired. You can also set a BitRate Tolerance percentage or touch the Default button to

Strona 98

Operator's Manual 919586 RevA 187 SEARCH SUBTYPE FIELDS Search Options fields in the center of the dialog allow you to restrict your search based

Strona 99

Serial Data Debug Solutions 188 919586 RevA USB2 Trigger Setup Detail The following topic provides specific control settings for a USB2 Trigger setup.

Strona 100

Operator's Manual 919586 RevA 189 Additional Dialog Controls Based on Packet Category Selections  With the Any Sync category selected, no addit

Strona 101 - Operator's Manual

Operator's Manual 919586 RevA 19 PROTOCOL RESULTS TABLE The protocol results table provides a quick and easy way to understand all of your protoc

Strona 102

Serial Data Debug Solutions 190 919586 RevA Protocol Error Pattern Type Selection Controls With the Protocol Error pattern type selected, the followin

Strona 103

Operator's Manual 919586 RevA 191 Using the USB3 Option Using the USB3 Option Overview USB 3.0 (also referred to as SuperSpeed USB) is a standard

Strona 104

Serial Data Debug Solutions 192 919586 RevA USB3 Decode Trace Annotations Like all trace annotations, USB3 Decode annotations are rectangular shadings

Strona 105

Operator's Manual 919586 RevA 193 USB3 Decode Table Column Details USB3 table column values available include the following: Make selections as

Strona 106

Serial Data Debug Solutions 194 919586 RevA USB3 Decode Search After clicking the Search button from the Decode dialog, the Zoom dialog is shown along

Strona 107

Operator's Manual 919586 RevA 195 Troubleshooting Storage, Peripherals, and Interconnects Issues Polarity Correction It is important to provide a

Strona 108

Serial Data Debug Solutions 196 919586 RevA Reference Dialog Area The lower portion of your oscilloscope screen is where information is shown, selecti

Strona 109

Operator's Manual 919586 RevA 197 TEXT ENTRY CONTROLS Most controls can be touched once and you can then provide a value using an attached (or do

Strona 110

Serial Data Debug Solutions 198 919586 RevA Note: The instrument's hard disk is partitioned into drive C: and drive D:. Drive C: contains the Win

Strona 111

Operator's Manual 919586 RevA 199 Slider Bar Some models provide what is known as a Slider Bar along the bottom of the screen when a keyboard is

Strona 112

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Internet: www.lecroy.com © 201

Strona 113

Serial Data Debug Solutions 20 919586 RevA Touching this colorized, first column heading opens the Decode Setup dialog. Touching any table row creates

Strona 114

Serial Data Debug Solutions 200 919586 RevA You can also find contact information for our offices on the LeCroy Web sites shown for the following regi

Strona 115

Operator's Manual 919586 RevA 201 Index 3 3b/4b, 50 5 5. Error Sub-Type and Right-Hand Dialog, 116 5. Timing Sub-Types and Right-Hand Dialogs, 11

Strona 116

Serial Data Debug Solutions 202 919586 RevA DigRF 3G Decode Search, 122 DigRF 3G Decode Setup Detail, 118 DigRF 3G Decode Table Column Details, 121 Di

Strona 117

Operator's Manual 919586 RevA 203 Mode command & Data (B'cast) Sub-Type and Right-Hand Dialogs, 114 Mode command & Data (Rcv) Sub-Ty

Strona 118 - Using the DigRF 3G Option

Serial Data Debug Solutions 204 919586 RevA The ProtoSync Toolset, 26 The Show Eye Control, 153 The Views Dialog, 153 Toolsets and Supported Protocols

Strona 119

Operator's Manual 919586 RevA 21  Checkboxes - Touch items to check the box and include them as table columns for a particular protocol.  Bit

Strona 120

Serial Data Debug Solutions 22 919586 RevA PLEASE NOTE THE FOLLOWING:  Search capabilities differ by protocol. For instance, SPI has no Address, so

Strona 121

Operator's Manual 919586 RevA 23 PLEASE NOTE THE FOLLOWING:  Since each serial protocol is quite different, serial trigger conditions are also

Strona 122 - Using the DigRF v4 Option

Serial Data Debug Solutions 24 919586 RevA The operations are organized in Digital to Analog, Timing, and Other columns on the pop-up for convenience.

Strona 123

Operator's Manual 919586 RevA 25 PX DIALOG Source Select the source for you parameter measurement. The source for a measurement made on a decoded

Strona 124

Serial Data Debug Solutions 26 919586 RevA Histicons Mark the Histicons checkbox to show or hide this additional statistical information in your lower

Strona 125

Operator's Manual 919586 RevA 27  Respective protocols in the Storage, Peripherals, and Interconnects section of this manual show how each prot

Strona 126

Serial Data Debug Solutions 28 919586 RevA OSCILLOSCOPE TABLE DISPLAY PROTOSYNC PACKET VIEW Note: Regarding Time (oscilloscope) and Time Stamp (prot

Strona 127

Operator's Manual 919586 RevA 29 If you don't have the Protocol Analysis software installed, this particular dialog instead shows a notific

Strona 128

Operator's Manual 919586 RevA iii TABLE OF CONTENTS Serial Data Debug Solutions Introduction ...

Strona 129

Serial Data Debug Solutions 30 919586 RevA  Please refer to LeCroy Protocol Analyzer Software user manuals at www.lecroy.com for information regardi

Strona 130

Operator's Manual 919586 RevA 31 The following screen-shot shows the oscilloscope Table display along with a corresponding CATC Protocol view.

Strona 131

Serial Data Debug Solutions 32 919586 RevA If the appropriate selections are made in the ProtoSync right-hand dialog, then simultaneously with the osc

Strona 132

Operator's Manual 919586 RevA 33 All TD packages provide basic tools to characterize embedded controller performance. The tools can be used on th

Strona 133

Serial Data Debug Solutions 34 919586 RevA CHARACTERIZATION USING CURSORS Use horizontal cursors to mark locations on the waveform where the time meas

Strona 134

Operator's Manual 919586 RevA 35  Delta Delay - Time between the 50% crossing of the first transition of two waveforms.  Delta Time @ Level -

Strona 135

Serial Data Debug Solutions 36 919586 RevA  Rise (10-90), Rise (20-80), Rise@Level - Transition time on the rising edge. Three selections are availab

Strona 136

Operator's Manual 919586 RevA 37 Isolating and Analyzing Serial Bus Activity ISOLATING AND ANALYZING SERIAL BUS ACTIVITY OVERVIEW The combination

Strona 137

Serial Data Debug Solutions 38 919586 RevA 2. Now, choose File → Save Waveform from the menu bar. The Auto Save dialog is shown where you can set up

Strona 138

Operator's Manual 919586 RevA 39 2. In the Sampling Mode area, select Sequence Mode. Touch the tab labeled Sequence that is now shown next to t

Strona 139

Serial Data Debug Solutions iv 919586 RevA I2C ...

Strona 140

Serial Data Debug Solutions 40 919586 RevA When you’ve acquired the set number of segments, the trigger STOPS and a display similar to the following i

Strona 141

Operator's Manual 919586 RevA 41 Display the trace by checking the TRACE ON checkbox. Select the segment for viewing by touching the Select tab a

Strona 142

Serial Data Debug Solutions 42 919586 RevA If you wish to change the segment that is decoded, just select a new segment from the Math trace dialog (as

Strona 143

Operator's Manual 919586 RevA 43  You can view the timestamps for each segment by selecting Vertical → Channels Status from the menu bar and s

Strona 144

Serial Data Debug Solutions 44 919586 RevA A display of timestamp information for each segment in the sequence acquisition is then shown (as follows).

Strona 145 - Using the MIPI M-PHY

Operator's Manual 919586 RevA 45 Serial Pattern Encoding Schemes - 8b/10b Serial Pattern Encoding Schemes Overview 8b/10b 8b/10b encoding is not

Strona 146

Serial Data Debug Solutions 46 919586 RevA The Basic Right-Hand Dialog The 8b/10b Basic Right-Hand dialog provides detailed fields and setup condition

Strona 147

Operator's Manual 919586 RevA 47 The Filter Right-Hand Dialog Use this dialog to specify which primitives for the protocol standard (selected fro

Strona 148

Serial Data Debug Solutions 48 919586 RevA HIGH SPEED SERIAL TRIGGER SETUP Access the High Speed Serial trigger dialog by touching the Trigger descrip

Strona 149

Operator's Manual 919586 RevA 49 Entering Symbolic 8b/10b Data Patterns When Symbolic Encoding is selected:  The tab on the High Speed Serial t

Strona 150

Operator's Manual 919586 RevA v FlexRaybus Trigger Setup Detail ...

Strona 151

Serial Data Debug Solutions 50 919586 RevA Encoding Table Reference For convenience, the following standard tables provide data for 5b/6b, 3b/4b, and

Strona 152

Operator's Manual 919586 RevA 51 Table 3-3.† For D.x.7, the Primary (D.x.P7) or Alternate (D.x.A7) encoding must be selected in order to avoid a

Strona 153

Serial Data Debug Solutions 52 919586 RevA 8b/10b Decode Search The 8b/10b Search right-hand dialog appears when the Zoom dialog is shown. Use the Pr

Strona 154

Operator's Manual 919586 RevA 53 General Purpose Embedded Protocols General Purpose Embedded Protocols Overview I2C I2C is a standardized protoco

Strona 155 - Using the SAS Option

Serial Data Debug Solutions 54 919586 RevA Oftentimes, I2C utilizes DATA bytes to specify sub-addresses for accessing memory locations in EEPROMs. Con

Strona 156

Operator's Manual 919586 RevA 55  Viewing - Select to view the protocol data in Binary, Hexadecimal, or ASCII modes. Note: If the trigger is se

Strona 157

Serial Data Debug Solutions 56 919586 RevA Selection of Trigger Type results in dynamic changes to the I2Cbus Trigger dialog. Simple I2C triggers, suc

Strona 158

Operator's Manual 919586 RevA 57  Include R/W bit - If 7-bit address length is selected, another selection will appear for whether the Read/Wri

Strona 159

Serial Data Debug Solutions 58 919586 RevA Conditional DATA trigger allows triggering on a range of DATA bytes that correspond to reads or writes to s

Strona 160

Operator's Manual 919586 RevA 59 The SPI trigger does not require use of a Chip Select line. In its place is the ability to set a minimum Interfr

Strona 161

Serial Data Debug Solutions vi 919586 RevA Using the DigRF 3G Option ...

Strona 162

Serial Data Debug Solutions 60 919586 RevA  Bits per Word and Bit Order - Provide a number of bits per word and select either MSB or LSB bit order f

Strona 163 - Using the PCIe Option

Operator's Manual 919586 RevA 61 The SPIbus trigger dialog is very flat, meaning there are few dynamic changes to the dialog based on selections

Strona 164

Serial Data Debug Solutions 62 919586 RevA 4. SETUP FORMAT Select either Binary or Hexadecimal (Hex) setup mode. The mode selected affects the format

Strona 165

Operator's Manual 919586 RevA 63 When the read InterFrame Time is smaller than the one you provided, subsequent bits are considered part of the s

Strona 166

Serial Data Debug Solutions 64 919586 RevA Touch the corresponding Setup... button for your decode. The Decode Setup... along with corresponding right

Strona 167

Operator's Manual 919586 RevA 65 UARTBUS LEVELS RIGHT-HAND DIALOG  Source 1 (DATA) Level Type and Vertical Level - The message decoding algori

Strona 168

Serial Data Debug Solutions 66 919586 RevA UART-RS232bus Trigger Setup Detail The following topic provides specific control settings for a UARTbus Tri

Strona 169

Operator's Manual 919586 RevA 67 5. DATA PATTERN SETUP  Data Value - Provide an appropriate value based on your Binary or Hexadecimal format se

Strona 170

Serial Data Debug Solutions 68 919586 RevA Automotive and Industrial Protocols Automotive and Industrial Protocols Overview CAN CAN is a vehicle bus d

Strona 171

Operator's Manual 919586 RevA 69 PLEASE NOTE THE FOLLOWING:  The CANbus option also provides Measure tools. Measure is a legacy toolset specif

Strona 172

Operator's Manual 919586 RevA vii SAS Decode Table Column Details ... 157

Strona 173

Serial Data Debug Solutions 70 919586 RevA Creating a CANbus Trigger Condition The CANbus Trigger dialog, with detail on some of the setup conditions,

Strona 174

Operator's Manual 919586 RevA 71  Remote - Only Frame ID Setup fields are enabled.  Data - Both Frame ID and Data Pattern ID Setup fields are

Strona 175 - Using the SATA Option

Serial Data Debug Solutions 72 919586 RevA The # Bits can be any value from 1 to 64. If you enter a value less than 1, it defaults to 1. If you enter

Strona 176

Operator's Manual 919586 RevA 73  Measure Timing, Accumulate Statistics, View Distribution - Instead of just looking at numerical values, graph

Strona 177

Serial Data Debug Solutions 74 919586 RevA LINbus Basic Right-Hand Dialog The Basic right-hand dialog provides detailed controls and setup conditions

Strona 178

Operator's Manual 919586 RevA 75 Select condition values by touching fields (using your finger, or use a mouse pointer). A pop-up is shown where

Strona 179

Serial Data Debug Solutions 76 919586 RevA 4. SETUP FORMAT With the Frame ID, ID + Data, or Error trigger types chosen, select either the Binary or He

Strona 180

Operator's Manual 919586 RevA 77 ERROR TRIGGER SETUP DETAIL 6b. Checksum Error Setup When the LINbus trigger selection is Error, use the Checksum

Strona 181

Serial Data Debug Solutions 78 919586 RevA  Ask your local LeCroy representative for more information about any Serial Data Debug Solution Protocols

Strona 182

Operator's Manual 919586 RevA 79 The message decoding algorithm setup is based the control values provided on this dialog. FlexRay is a tri-level

Strona 183 - Using the USB2 Option

Serial Data Debug Solutions viii 919586 RevA Reference ...

Strona 184

Serial Data Debug Solutions 80 919586 RevA FlexRaybus Trigger Setup Detail The following topic provides specific control settings for a FlexRaybus Tri

Strona 185

Operator's Manual 919586 RevA 81  Frame - When selected, the Setup Format, Frame ID Setup, Cycle Count, and Frame Qualifiers fields are shown a

Strona 186

Serial Data Debug Solutions 82 919586 RevA Note: The Cycle Count fields are shown, but disabled when TSS (Start) is selected as the FlexRaybus trigger

Strona 187

Operator's Manual 919586 RevA 83 Include or exclude Channel Idle Delimiter (CID), CAS/MTS, or Wakeup Pattern from your trigger by checking our un

Strona 188

Serial Data Debug Solutions 84 919586 RevA EYE DIAGRAM AND MASK TEST SETUP DETAIL The Left Hand side of the FlexRay Physical Layer tab has all the set

Strona 189

Operator's Manual 919586 RevA 85 Mask Test Display The FlexRay TDP option allows you to verify signal integrity of the communication channel and

Strona 190

Serial Data Debug Solutions 86 919586 RevA FlexRaybus Physical Layer Measurement Parameters The FlexRaybus option provides four measurement parameters

Strona 191 - Using the USB3 Option

Operator's Manual 919586 RevA 87 Serial Audio Protocol Serial Audio Protocol Overview I2S I2S , LeCroy's AudioBus option, includes I2S, LJ,

Strona 192

Serial Data Debug Solutions 88 919586 RevA TRIGGER, DECODE, AND GRAPH LeCroy offers two methods for converting your digital signals into waveforms - V

Strona 193

Operator's Manual 919586 RevA 89  The View Audio button shows the Audio Track Wizard (as follows) which sets up Math traces for the audio chann

Strona 194

Operator's Manual 919586 RevA 9 Serial Data Debug Solutions Introduction Overview LeCroy's Serial Data Debug Solutions (SDDS) provide differ

Strona 195

Serial Data Debug Solutions 90 919586 RevA AUDIO DIALOG  Viewing - Select to view the protocol data in Binary, Hexadecimal (Hex), or ASCII modes. 

Strona 196 - Reference

Operator's Manual 919586 RevA 91  WS (or FRS, for TDM Protocol Variant) - The Word Select field is enabled when using the LJ and RJ AudioBus pr

Strona 197

Serial Data Debug Solutions 92 919586 RevA The AudioBus Trigger dialog, with detail on some of the setup conditions, is shown in the following topics.

Strona 198

Operator's Manual 919586 RevA 93  RJ is similar to I2S with the exception that the LSB occurs at the end of the frame sync, as follows. RJ Var

Strona 199 - Contact LeCroy for Support

Serial Data Debug Solutions 94 919586 RevA 4. AUDIO CHANNEL  Channel - Choose Left or Right as desired.  Bit Order - This field is only enabled wh

Strona 200

Operator's Manual 919586 RevA 95  Mute Setup... - Provide values using the pop-up numeric keypad for Noise Floor and Duration (# Frames) amount

Strona 201

Serial Data Debug Solutions 96 919586 RevA Note: For Rising or Falling Edge Types, a Data Value display field is shown and is converted based on your

Strona 202

Operator's Manual 919586 RevA 97 Military and Avionic Protocols Military and Avionic Protocols Overview ARINC 429 Aircraft Radio Incorporated, or

Strona 203

Serial Data Debug Solutions 98 919586 RevA ARINC 429 Basic Right-Hand Dialog The Basic right-hand dialog provides detailed controls and setup conditio

Strona 204

Operator's Manual 919586 RevA 99 User Label Description Files Effective use of a User Label Description File (ULDF) provides several viewing mode