QPHY-MOST50e
MOST50 ePHY Serial Data
Operators Manual
Revision B – March, 2012
Relating to the Following Release
Versions:
Software Version Rev. 6.8
MOST50e Script Rev. 1.1
Style Sheet Rev. 1.2
Przeglądanie stron 0
1 2 3 4 5 6 ... 20 21

Podsumowanie treści

Strona 1

QPHY-MOST50e MOST50 ePHY Serial Data Operator’s Manual Revision B – March, 2012 Relating to the Following Release Versions: • Software V

Strona 2

10 920457 Rev B Accessing the QPHY-MOST50e Software using QualiPHY This topic provides a basic overview of QualiPHY’s capabilities. Please refer

Strona 3

QPHY-MOST50e Software Option 920457 Rev B 11 4. Click the Configuration button in the QualiPHY main menu: 5. Select a configuration from the po

Strona 4 - 4 920457 Rev B

12 920457 Rev B Customizing QualiPHY The predefined configurations in the Configuration screen cannot be modified. However, you can create your

Strona 5

QPHY-MOST50e Software Option 920457 Rev B 13 Creating Custom Configurations Beginning with any of the pre-loaded configurations, 1. Click on th

Strona 6 - USING QUALIPHY MOST50 EPHY

14 920457 Rev B Figure 6 - Variable Setup and Limits Manager windows

Strona 7

QPHY-MOST50e Software Option 920457 Rev B 15 QPHY-MOST50e Operation After pressing Start in the QualiPHY menu, the software instructs how to set

Strona 8 - 8 920457 Rev B

16 920457 Rev B MOST50 EPHY MEASUREMENT PREPARATION Before beginning any test or data acquisition, the oscilloscope must be warmed for at least 2

Strona 9

QPHY-MOST50e Software Option 920457 Rev B 17 QPHY-MOST50E VARIABLES Default Bitrate Specifies whether the bitrate is based on 48 kHz or 44.1 kHz f

Strona 10 - 10 920457 Rev B

18 920457 Rev B Path to Demo waveforms Specifies the location of the stored waveforms for Demo Mode. QPHY-MOST50E LIMIT SETS The limits in use

Strona 11 - QPHY-MOST50e Software Option

QPHY-MOST50e Software Option 920457 Rev B 19 Eye Diagram Testing 1.1, 2.1, 3.1, 4.1 This test is performed at all test points and creates an eye

Strona 12 - 12 920457 Rev B

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Internet: www.lecroy.com © 2009 by

Strona 13

20 920457 Rev B Transfer Jitter Testing 1.2, 2.2 This test is performed at points SP1E and SP2E. The oscilloscope captures a long signal record

Strona 14 - 14 920457 Rev B

QPHY-MOST50e Software Option 920457 Rev B 21 Master, Slave Mode Device Testing Timing Master Device A Timing Master device is responsible for s

Strona 15

QPHY-MOST50e Software Option 920457 Rev B 3 TABLE OF CONTENTS INTRODUCTION TO QUALIPHY MOST50 EPHY ...

Strona 16 - 920457 Rev B

4 920457 Rev B TABLE OF FIGURES Figure 1 - Report menu in QualiPHY General Setup...

Strona 17

QPHY-MOST50e Software Option 920457 Rev B 5 INTRODUCTION TO QUALIPHY MOST50 EPHY QPHY-MOST50e is an automated test package performing all of the

Strona 18 - QPHY-MOST50E LIMIT SETS

6 920457 Rev B USING QUALIPHY MOST50 EPHY QualiPHY MOST50 ePHY guides the user, step-by-step, through each of the tests described in the specifi

Strona 19

QPHY-MOST50e Software Option 920457 Rev B 7 QUALIPHY COMPLIANCE TEST PLATFORM QualiPHY is LeCroy’s compliance test framework which leads the use

Strona 20 - 20 920457 Rev B

8 920457 Rev B See the QualiPHY Operator’s Manual for more information on how to use the QualiPHY framework. Figure 2 - The Test Report includ

Strona 21

QPHY-MOST50e Software Option 920457 Rev B 9 Oscilloscope Option Key Installation The required option keys must be purchased to enable the QPHY-MOS