LeCroy Corporation Switching Views
206
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Figure 3.32: SATA: Bus Utilization View for Pending ATA IO
Available Bus Utilization Views are:
Pending SCSI IO (for SAS)
Pending ATA IO (for SATA)
Hovering the mouse over the graph heading displays the graph legend:
GotoATA/SCSICmd.#: Jump to command.
SynchronizewithTraceView: Synchronize all open views to that location in the
trace.
FittoGraphArea: Zoom to fit.
Hide: Do not display the graph.
To synchronize all open views to that location in the trace, doubleclick the graph.
Bus Utilization Buttons
The Bus Utilization window has a row of buttons for changing the format of the displayed
data. The buttons have the following functions:
Horizontal zoom in Vertical zoom in
Horizontal zoom out Vertical zoom out
Graph Areas
Presents options for displaying additional
graphs.
Click and Drag zoom
Click diagonally to select and
zoom in on part of the graph.
Hide graph. Graph legend (see previous
page)