 Sierra M64 SAS/SATA Protocol Analyzer User Manual 169
Target and Device Emulation
LeCroy Corporation
Open Connection Definition
Incoming Frame Settings
1. In the OpenConnection dialog, enter a value for the IncomingOpenFrameNumber
and the NumberofErrorsin the corresponding text box.
2. Click the down arrow next to the PrimitiveResponse:drop down list box, choose a
primitive response, and enter a value for the DelayinSendingResponse text box.
3. Enter a value for OutgoingOpenFrameNumber and NumberofErrorsin the
corresponding text box.
Outgoing Frame Settings
Click OutgoingOpenFrameErrorSettings to display the OpenFrameSetting dialog.
Check the errors to introduce and click OK.
Figure 2.175: SAS: Open Frame Setting
Close Connection Definition
1. In the CloseConnection dialog, enter a value for the ErroneousCloseConnection
Numberand the NumberofErrorsin the corresponding text box.
2. Click the down arrow next to the CloseSequenceTypedrop down list box, then
choose a closing sequence.
3. For a delay in sending, click the DelayinSendingcheck box, click the down arrow on
the associated drop down list box, choose what to delay, and enter a value for the
DelayTime.
Figure 2.176: SAS: Delay in Sending