Exercise and Capture
LeCroy Corporation
Incoming SCSI Frame Settings
Before selecting Incoming Frame Settings, select the Types Of Frames and the
Frame Number on which to inject an error. Then check Incoming Frame in the Generate
Error On area and then the enabled Settings button to display the Incoming Frame Setting
dialog.
Figure 2.137: SAS: Incoming Frame Setting Dialog (SCSI)
Handshake Error
Check HandshakeError and select NAKCRCError,NoHandshake, or Primitive and a
Primitive Type.
Defer Handshake
Check the DeferHandshakeafter check box and enter a value for the time to defer the
handshake.
FIS Options (SATA only)
If you select Fr
ame>HosttoDevice, Frame>DMASetup, orFrame>Data, the system
adds an FIS line. At the end of the line is an Options button that opens an
Outgoing Frame Setting dialog.
Figure 2.138: SATA: FIS Options Outgoing Frame Setting Dialog