PETracer Software User Manual Chapter 8: Reports and Tools
Teledyne LeCroy 85
8.2 Error Summary
The Error Summary dialog box displays the number of errors for each event and the
packet containing the errors.
Select Reports > Error Summary to obtain the Error Summary dialog box.
AHCI Error Summary
The AHCI Error Summary dialog is a sub-entry for the main Error Summary dialog. It
displays the number of errors for each AHCI transaction containing the errors.
Select Reports > Error Summary to open the Error Summary dialog .
ThefivetypesofAHCIerrorsaredescribebelow:
Reserved Field not Zeroes
One or more fields inside the AHCI transaction are not filled with all 0s. The AHCI
specification states that all reserved fields and registers must be filled with 0s
Note: Reserved fields for AHCI level are not displayed when filled with all 0s.