Teledyne-lecroy WaveExpert 9000_NRO9000_SDA100G Getting Started Ma Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Teledyne-lecroy WaveExpert 9000_NRO9000_SDA100G Getting Started Ma. Teledyne LeCroy WaveExpert 9000_NRO9000_SDA100G Getting Started Manual User Manual [en] [de] [fr] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 50
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
L
L
E
E
C
C
R
R
O
O
Y
Y
W
W
A
A
V
V
E
E
E
E
X
X
P
P
E
E
R
R
T
T
9
9
0
0
0
0
0
0
N
N
R
R
O
O
9
9
0
0
0
0
0
0
S
S
D
D
A
A
1
1
0
0
0
0
G
G
G
G
E
E
T
T
T
T
I
I
N
N
G
G
S
S
T
T
A
A
R
R
T
T
E
E
D
D
M
M
A
A
N
N
U
U
A
A
L
L
S
S
E
E
P
P
T
T
E
E
M
M
B
B
E
E
R
R
2
2
0
0
0
0
5
5
Przeglądanie stron 0
1 2 3 4 5 6 ... 49 50

Podsumowanie treści

Strona 1

LLEECCRROOYY WWAAVVEEEEXXPPEERRTT 99000000 NNRROO 99000000 SSDDAA 110000GG GGEETTTTIINNGG SSTTAARRTTEEDD MMAANNUUAALL SSEEPPTTEEMMBBEERR

Strona 2

8 ISSUED: September 2005 WE-GS-E Rev A Note: The design of the scope has been verified to conform to EN 61010-1 safety standard per the following

Strona 3

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 9 AC Power Source Note: The scope automatically adapts itself to the AC line i

Strona 4

10 ISSUED: September 2005 WE-GS-E Rev A Standby (Power) Switch and Scope Operational States The front Standby (Power) switch controls the operatio

Strona 5

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 11 Calibration The recommended calibration interval is one year. Calibration s

Strona 6 - BLANK PAGE

12 ISSUED: September 2005 WE-GS-E Rev A When Your Scope is Delivered Check that You Have Everything First, verify that all items on the packing li

Strona 7 - Introduction

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 13 has expired. Installation, training, enhancements, and on-site repairs — am

Strona 8 - Safety Requirements

14 ISSUED: September 2005 WE-GS-E Rev A and testing Your Software. If you are an entity, only one designated individual within your organization,

Strona 9

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 15 Objective”) only if: (A) doing so is necessary to achieve the Permitted Obj

Strona 10

16 ISSUED: September 2005 WE-GS-E Rev A property laws and treaties. You will not take any action inconsistent with such title and ownership. This

Strona 11 - 90 to 132 V

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 17 subsequent disclosure, or (e) independently developed by the receiving part

Strona 12

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY 10977-6499 Tel: (845) 578 6020 Fax: (845) 578 5985 Internet: www.lecroy.com © 2005 by

Strona 13

18 ISSUED: September 2005 WE-GS-E Rev A exported or otherwise accessed, shipped or transported in violation of applicable laws and regulations. 7.

Strona 14 - When Your Scope is Delivered

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 19 8.2 No Agency. Nothing contained in this EULA will be deemed to constitute

Strona 15 - ® X-Stream Software

20 ISSUED: September 2005 WE-GS-E Rev A Installation Hardware Connections for WaveMaster, WavePro, SDA, and DDA Models Rear Panel Diagram: (1) Mou

Strona 16

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 21 SOFTWARE You can find out the scope's software and hardware configurat

Strona 17

22 ISSUED: September 2005 WE-GS-E Rev A System Recovery – Windows XP Scopes Your oscilloscope was designed to operate very reliably for many years

Strona 18

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 23 5. Then the cME console End User License Agreement is displayed. Read the

Strona 19

24 ISSUED: September 2005 WE-GS-E Rev A 7. The FirstWare Recover splash screen is displayed momentarily: 8. The recovery starts, and the FirstW

Strona 20

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 25 9. After the recovery is completed, the X-Stream software installer screen

Strona 21

26 ISSUED: September 2005 WE-GS-E Rev A 2. Select an activation method: internet or phone. Then click Next. 3. If you elected to activate by i

Strona 22 - Installation

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 27 4. If you elected to activate by phone, select the country the scope is lo

Strona 23 - EFAULT SETUP button on the

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 1 INTRODUCTION...

Strona 24

28 ISSUED: September 2005 WE-GS-E Rev A 6. Check the revision levels of the X-Stream software, virus definitions, and Windows updates. Visit the

Strona 25

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 29 Connecting to a Signal Electrical Modules The sampling modules are equipped

Strona 26

30 ISSUED: September 2005 WE-GS-E Rev A Connector Torque In order to maintain bandwidth performance and minimize loss, connections to the instrume

Strona 27

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 31 The optical modules come standard with an FC-PC connector, and adapters are

Strona 28

32 ISSUED: September 2005 WE-GS-E Rev A Front Panel Controls Front Panel Buttons and Knobs The control buttons of the instrument's front pane

Strona 29

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 33 Then use the keypad to type in the value. The SELECT button steps through a

Strona 30

34 ISSUED: September 2005 WE-GS-E Rev A Vertical Knobs and Buttons: OFFSET – Adjusts the vertical offset of a channel. VOLTS/DIV – Adjusts the Vol

Strona 31 - Connecting to a Signal

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 35 Trigger Knobs and Buttons: LEVEL – Selects the trigger threshold level when

Strona 32

36 ISSUED: September 2005 WE-GS-E Rev A Wavepilot Control Knobs and Buttons: POSITION – Adjusts the horizontal position of a zoom trace on the dis

Strona 33

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 37 Special Features Buttons: AUTO SETUP – Automatically sets the scope's

Strona 34 - Front Panel Controls

2 ISSUED: September 2005 WE-GS-E Rev A Restoring Software...2

Strona 35

38 ISSUED: September 2005 WE-GS-E Rev A QUICKZOOM (toggle switch) –Automatically displays magnified views of up to four signal inputs on multip

Strona 36

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 39 Many of the menu bar buttons give you access to the same functions as do th

Strona 37

40 ISSUED: September 2005 WE-GS-E Rev A On-screen Toolbars, Icons, and Dialog Boxes Toolbar Buttons The toolbar buttons at the top of the scope&ap

Strona 38

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 41 (icon in Channels dialog zooms one trace) (zooms all displayed trace

Strona 39

42 ISSUED: September 2005 WE-GS-E Rev A (then Utilities Setup...) Scope Icons The icons that you see in the dialog areas of the scope are touch

Strona 40

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 43 Screen Layout The scope screen is divided into three areas: • tool bar • s

Strona 41

44 ISSUED: September 2005 WE-GS-E Rev A Trace Descriptors Vertical and horizontal trace descriptors, or labels, are displayed below the grid. They

Strona 42

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 45 2. To turn on a math function trace, touch Math in the toolbar, then Math

Strona 43

46 ISSUED: September 2005 WE-GS-E Rev A Introduction to WaveShape Analysis This section is a brief reference to the basic tools available to perfo

Strona 44

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 47 Standard Horizontal Parameters These are the default Standard Horizontal Pa

Strona 45 - Screen Layout

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 3 Toolbar Buttons...

Strona 46 - Trace Descriptors

48 ISSUED: September 2005 WE-GS-E Rev A Parameter Analysis Trend measurements A trend of a measurement parameter is a line graph with a measuremen

Strona 47

4 ISSUED: September 2005 WE-GS-E Rev A BLANK PAGE

Strona 48

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 5 Introduction This brief guide includes important safety and installation inf

Strona 49

6 ISSUED: September 2005 WE-GS-E Rev A Safety Requirements This section contains information and warnings that must be observed to keep the scope

Strona 50 - Parameter Analysis

WaveExpert Getting Started Guide WE-GS-E Rev A ISSUED: September 2005 7 CAUTION The CAUTION sign indicates a potential hazard. It calls attention to