LeCroy Corporation Verification Script Engine Reference Manual Version 1.01
5.2 Trace event-dependent set of members
This set of members is defined and can be used only for a specific events or after calling some
functions filling out some of the variables:
5.2.1 Primitives
in.Primitive – 4-byte value of the Primitive
in.Count – Primitive count
5.2.2 OOB
in.OOBType – OOB Types are defind as:
SAS_OOB_UNDETERMINED = 0
SAS_OOB_COMWAKE = 1
SAS_OOB_COMRESET = 2
SAS_OOB_COMSAS = 3
in.OOBBurstIdleList – list of pairs (<burst_or_idle>, <count>), where <burst_or_idle> is 0 for
idle and 1 for burst. Example:
oob_burst_idle_list = in.OOBBurstIdleList;
for ( i = 0; i < sizeof( oob_burst_idle_list ); i++ )
{
oob_burst_idle = oob_burst_idle_list[ i ];
report += repIndent;
select
{
oob_burst_idle[ 0 ] == SAS_OOB_ELEMENTTYPE_IDLE :
report += Format( "OOBIdle : %ld oobi\n", i, oob_burst_idle[ 1 ] );
oob_burst_idle[ 0 ] == SAS_OOB_ELEMENTTYPE_BURST :
report += Format( "OOBBurst : %ld oobi\n", i, oob_burst_idle[ 1 ] );
};
}
5.2.3 SAS/SATA Generic Frame members
in.Payload - bit source of the frame/sequence payload (you can extract any necessary
information using GetNBits(), NextNBits() or PeekNBits() functions—please refer to the CSL Manual
for details about these functions)
in.PayloadLength - the length (in bytes of the retrieved payload)
in.SOF,
in.StartOfFrame – 4-byte value of Start of frame primitive
in.EOF,
in.EndOfFrame – 4-byte value of End of frame primitive
in.CRC – CRC value as transmitted