ISetting
30
SetAnalyzerSpeed
Declaration: long SetAnalyzerSpeed(short sAnalyzerSpeed)
Input(s): sAnalyzerSpeed sets the speed of the analyzer.
Valid analyzer speed types are defined in API Constants.
Return Value: Zero if the SetAnalyzerSpeed was successful. Otherwise, non-zero.
Each non-zero value indicates an error code.
Remark: This function sets the speed of the analyzer.
See Also: API Errors
GetAnalyzerSpeed
Declaration: short GetAnalyzerSpeed()
Input(s): None
Return Value: Speed type of the analyzer.
Valid analyzer speed types are defined in API Constants.
Remark: This function returns the speed of the analyzer.
SetExerciserLoopCounter
Declaration: long SetExerciserLoopCounter(short sLoopCounter)
Input(s): sLoopCounter sets loop counter of exerciser. This value can be
between 2 and 255.
Return Value:
Zero if the SetExerciserLoopCounter was successful.
Otherwise, non-zero. Each non-zero value indicates an error code.
Remark: This function sets the loop counter of the exerciser.
See Also API Errors
Get ExerciserLoopCounter
Declaration: short GetExerciserLoopCounter ()
Input(s) None
Return Value: Loop counter of the exerciser
Remark: Returns the loop counter of the exerciser.
See Also: API Errors